Gene Walshaw HITA Certified Master Home Inspector TN State License #101 |
FROM MANSIONS ………………… TO LOG HOMES WE ARE YOUR HOME INSPECTION EXPERTS! |
|
|||
Prepared For:
Jayne Norris
Property Address:
1234 Buyer's Street
Knoxville, TN 37918
![]() |
| Date: 12/7/2005 | Time: 9:07 AM | Report ID: |
| Property: 1234 Buyer's Street Knoxville, TN 37918 |
Customer: Jayne Norris |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: Over 50 Years |
Client Is Present: Yes |
Weather: Clear |
| Temperature: Below 60 |
Rain in last 3 days: Yes |
|
Best Choice Inspections 3109 Ellistown Road |
|
Customer |
|
Property Address |
| 1.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | ||||
| Repair or Replace | |||||
|
Three areas of major foundation block movement visible in the
crawl space:
a) Under the right rear corner of kitchen. b) Near pier under the far right end of the main center girder beam. c) Near the outside heat pump unit. House is over 30 years old and some foundation movement is common. Gutter downspout near the foundation appears to have been recently re-routed away from the foundation walls and crawl space is soil s relatively dry now. Recommend evaluation by a qualified foundation repair specialist for appropriate foundation wall and/or footer repairs.
|
|||||
| 1.2 | COLUMNS OR PIERS | ||||
| Inspected, Repair or Replace | |||||
|
Main flooring center girder is resting on several unmortared,
loose pier blocks and bricks. No concrete footings found under
these piers. Girder is less than 6 inches from crawl space soil.
Recommend repair by a licensed general contractor.
|
|||||
| 1.3 | FLOORS (Structural) | ||||
| Repair or Replace | |||||
|
Floor joists are sagging in kitchen and living room. All floor
joists in flooring system are 2" x 8" boards on approximate. 24"
centers. Total span is approximately 12 feet between main center
girder and front/rear foundation walls. Joists appear to be
over-spanned according to standard building
practices. Recommend a licensed general contractor evaluate
floor joists for installation of proper reinforcement.
|
|||||
|
|
|||||
| 1.4 | CEILINGS (structural) | ||||
| Repair or Replace | |||||
|
Ceiling joist pairs do not join together above main load bearing
wall. One joist is twisted above front bedroom ceiling in attic.
Suggest a qualified tradesman install wood 2" x 6" blocking
between all ceiling joists.
|
|||||
| 1.5 | ROOF STRUCTURE AND ATTIC | ||||
| Repair or Replace | |||||
|
2 x 4 rafters for roof have two 1 x 6 braces that are are broken
or bowed. All other rafters are also braced with undersized 1 x
6 boards. Recommend a licensed contractor replace the two
damaged braces with 2 x 6 lumber and reinforce ("sister") all
other braces with heavier boards.
|
|||||
|
Three 1" x 6" roofing deck boards are damaged between rafters.
Recommend brace the underside of these boards to strengthen.
Suggest repair by a qualified roofing contractor or carpenter.
|
|||||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | ||
| Repair or Replace | |||
|
All four front porch columns are deteriorated starting at
concrete floor and going up 4" to 9" above floor. Suggest repair
or replace all columns by a qualified, skilled tradesman. (Picture
1)
|
|||
| 3.2 | ROOF COVERINGS | ||
| Repair or Replace | |||
|
On the left side of front porch roof 6 or more shingles are
raised above the roof surface. Recommend remove pieces of first
layer shingles fastened underneath the raised shingles and seal
flush with roofing cement. Suggest repair by a qualified roofing
contractor.
|
|||
| 4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS | ||
| Repair or Replace | |||
|
Water heater is located below ground level in crawlspace and is
not allowed. This can cause damage to the unit or shorten its
life span. Recommend a licensed plumber inspect further and
repair as necessary.
|
|||
| 5.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVER CURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | ||
| Repair or Replace | |||
|
Main panel box is located at outside at. Panel is improperly
grounded with two ground wires attached to a one-wire rated
grounding clamp on the grounding rod. This is a safety issue
that needs to be corrected. Recommend repair by a licensed
electrician.
|
|||
|
Four abandoned wires in main outside panel box have uncapped
ends. Recommend a licensed electrician cap and tape wire ends
and determine location of other ends.
|
|||
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | ||
| Repair or Replace | |||
|
Two exposed splice's at ceiling in attic space. Exposed wiring
is considered unsafe until repaired. Recommend licensed
electrician install a covered junction box at each splice.
|
|||
| 9.0 | INSULATION AND VAPOR moisture bearers (in unfinished spaces) | ||
| Repair or Replace | |||
|
Ceiling insulation in attic is less than six inches in
thickness. Recommend adding insulation to make ceiling an R-33
value or greater.
|
|||
|
Moisture barrier missing on part of crawl space soil. Suggest
install 6 mil polyethylene wall-to-wall. Gray electric
disconnect box in background is not active.
|
|||
| 10.1 | RANGES/OVENS - COOKTOPS | ||
| Repair or Replace | |||
|
Range oven cord binds on range frame and storage drawer bumps
cord. Recommend reinstall range outlet in a horizontal position
by a licensed electrician.
|
|||
Prepared Using HomeGauge
http://www.homegauge.com SHGI
(c) 2000-2004 : Licensed To Best Choice Inspections
| FOUNDATION: MASONRY BLOCK |
METHOD USED TO OBSERVE
CRAWLSPACE: CRAWLED LIMITED ACCESS |
FLOOR STRUCTURE: 2 X 8 WOOD JOISTS WOOD BEAMS |
| WALL STRUCTURE: 2 X 4 WOOD |
COLUMNS OR PIERS: WOOD PIERS MASONRY BLOCK |
CEILING STRUCTURE: 2X6 |
| ROOF STRUCTURE: 2X4 RAFTERS |
ROOF-TYPE: GABLE |
METHOD USED TO OBSERVE
ATTIC: WALKED |
| ATTIC INFO: SCUTTLE HOLE |
| IN | NI | NP | RR | ||
| 1.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | X | |||
| 1.1 | WALLS (Structural) | X | |||
| 1.2 | COLUMNS OR PIERS | X | X | ||
| 1.3 | FLOORS (Structural) | X | |||
| 1.4 | CEILINGS (structural) | X | |||
| 1.5 | ROOF STRUCTURE AND ATTIC | X | |||
| IN | NI | NP | RR | ||
| SIDING STYLE: LAP |
SIDING MATERIAL: VINYL |
EXTERIOR ENTRY DOORS: STEEL |
| APPURTENANCE: DECK WITH STEPS COVERED PORCH |
DRIVEWAY: ASPHALT |
| IN | NI | NP | RR | ||
| 2.0 | WALL CLADDING FLASHING AND TRIM | X | |||
| 2.1 | DOORS (Exterior) | X | |||
| 2.2 | WINDOWS | X | |||
| 2.3 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) | X | |||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | X | |||
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) | X | |||
| 2.6 | EAVES, SOFFITS AND FASCIAS | X | |||
| IN | NI | NP | RR | ||
| ROOF COVERING: 3-TAB FIBERGLASS |
VIEWED ROOF COVERING FROM: WALKED ROOF |
| IN | NI | NP | RR | ||
| 3.0 | FLASHINGS | X | |||
| 3.1 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | X | |||
| 3.2 | ROOF COVERINGS | X | |||
| 3.3 | ROOFING DRAINAGE SYSTEMS | X | |||
| IN | NI | NP | RR | ||
| WATER SOURCE: PUBLIC |
WATER FILTERS: NONE |
PLUMBING SUPPLY: NOT VISIBLE |
| PLUMBING DISTRIBUTION: GALVANIZED COPPER |
WASHER DRAIN SIZE: 2" DIAMETER |
PLUMBING WASTE: PVC |
| WATER HEATER POWER SOURCE: ELECTRIC |
CAPACITY: 40 GAL (1-2 PEOPLE) |
MANUFACTURER: BRADFORD-WHITE |
| IN | NI | NP | RR | ||
| 4.0 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS | X | |||
| 4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | X | |||
| 4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS | X | |||
| 4.3 | MAIN WATER SHUT-OFF DEVICE (Describe location) | X | |||
| 4.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | X | |||
| 4.5 | SUMP PUMP | X | |||
| IN | NI | NP | RR | ||
| ELECTRICAL SERVICE
CONDUCTORS: OVERHEAD SERVICE 220 VOLTS |
PANEL CAPACITY: 200 AMP |
PANEL TYPE: CIRCUIT BREAKERS |
| BRANCH WIRE 15 and 20 AMP: COPPER |
WIRING METHODS: ROMEX |
| IN | NI | NP | RR | ||
| 5.0 | SERVICE ENTRANCE CONDUCTORS | X | |||
| 5.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | X | |||
| 5.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE | X | |||
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | X | |||
| 5.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE | X | |||
| 5.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) | X | |||
| 5.6 | SMOKE DETECTORS | X | |||
| IN | NI | NP | RR | ||
a) Rear bedroom: outlet under window.
b) Front bedroom: outlet under window facing front yard.
c) Living room: two outlets, one under each window.
Recommend a licensed electrician ground these outlets or make them GFCI protected and mark accordingly.
| HEAT TYPE: HEAT PUMP (FORCED AIR) |
ENERGY SOURCE: ELECTRIC |
NUMBER OF HEAT SYSTEMS
(excluding wood): ONE |
| HEAT SYSTEM BRAND: GOODMAN |
DUCTWORK: INSULATED |
TYPES OF FIREPLACES: NONE |
| IN | NI | NP | RR | ||
| 6.0 | HEATING EQUIPMENT | X | |||
| 6.1 | NORMAL OPERATING CONTROLS | X | |||
| 6.2 | AUTOMATIC SAFETY CONTROLS | X | |||
| 6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | X | |||
| 6.4 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM | X | |||
| IN | NI | NP | RR | ||
| COOLING EQUIPMENT TYPE: HEAT-PUMP |
COOLING EQUIPMENT ENERGY
SOURCE: ELECTRICITY |
CENTRAL AIR MANUFACTURER: GOODMAN |
| NUMBER OF A/C UNITS: ONE |
| IN | NI | NP | RR | ||
| 7.0 | COOLING AND AIR HANDLER EQUIPMENT | X | |||
| 7.1 | NORMAL OPERATING CONTROLS | X | |||
| 7.2 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | X | |||
| IN | NI | NP | RR | ||
| CEILING MATERIALS: SHEETROCK |
WALL MATERIAL: SHEETROCK |
FLOOR COVERING(S): CARPET VINYL |
| INTERIOR DOORS: MASONITE |
WINDOW TYPES: THERMAL/INSULATED SINGLE-HUNG |
| IN | NI | NP | RR | ||
| 8.0 | CEILINGS | X | |||
| 8.1 | WALLS | X | |||
| 8.2 | FLOORS | X | |||
| 8.3 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | X | |||
| 8.4 | DOORS (REPRESENTATIVE NUMBER) | X | |||
| 8.5 | WINDOWS (REPRESENTATIVE NUMBER) | X | |||
| IN | NI | NP | RR | ||
| ATTIC INSULATION: BLOWN BATT FIBERGLASS CELLULOSE |
R- VALUE: BELOW R-19 |
VENTILATION: GABLE VENTS |
| EXHAUST FAN TYPES: NONE |
DRYER POWER SOURCE: 22O ELECTRIC |
DRYER VENT: METAL |
| IN | NI | NP | RR | ||
| 9.0 | INSULATION AND VAPOR moisture bearers (in unfinished spaces) | X | |||
| 9.1 | VENTILATION OF ATTIC AND FOUNDATION AREAS | X | |||
| 9.2 | VENTING SYSTEMS (Kitchens, baths and laundry) | X | |||
| IN | NI | NP | RR | ||
| DISHWASHER: KENMORE |
DISPOSER: BADGER |
EXHAUST/RANGE HOOD: RE-CIRCULATE |
| RANGE/OVEN: MAGIC CHEF |
BUILT-IN MICROWAVE: NONE |
TRASH COMPACTORS: NONE |
| REFRIGERATOR: GENERAL ELECTRIC |
| IN | NI | NP | RR | ||
| 10.0 | DISHWASHER | X | |||
| 10.1 | RANGES/OVENS/COOKTOPS | X | |||
| 10.2 | RANGE HOOD | X | |||
| 10.3 | TRASH COMPACTOR | X | |||
| 10.4 | FOOD WASTE DISPOSER | X | |||
| 10.5 | MICROWAVE COOKING EQUIPMENT | X | |||
| IN | NI | NP | RR | ||
|
|
INVOICE |
| Best Choice Inspections 3109 Ellistown Road Knoxville, TN 37924 865-607-2934 Inspected By: Gene Walshaw |
Inspection Date: 12/7/2005 Report ID: |
| Customer Info: | Inspection Property: |
|
Jayne Norris 789 Broad Street Knoxville TN 37924 Customer's Real Estate Professional: |
1234 Buyer's Street Knoxville, TN 37918 |
Inspection Fee:
|
||||||||
Tax $0.00 |
||||||||
| Total Price $249.00 |
Payment Method:
Payment Status:
Note:
a) Under the right rear corner of kitchen.
b) Near pier under the far right end of the main center girder beam.
c) Near the outside heat pump unit.
House is over 30 years old and some foundation movement is common. Gutter downspout near the foundation appears to have been recently re-routed away from the foundation walls and crawl space is soil s relatively dry now. Recommend evaluation by a qualified foundation repair specialist for appropriate foundation wall and/or footer repairs.